FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-47
(29) C0400: Exposure Lamp’s failure to turn ON
(30) C0410: Exposure Lamp turning ON at abnormal timing
<Detection Timing>
<Action>
Malfunction Code
Description
C0400
The output from the CCD Sensor is a predetermined value or less
during CCD Sensor gain adjustment.
C0410
The average output value of the CCD Sensor with the Scanner at
its standby position is a predetermined value or more at the end of
a scan job.
Relevant Electrical Parts
Scanner Assy
Flat Cable
Image Processing Board (PWB-C)
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the flat cable for proper
connection and correct or
change as necessary.
—
—
—
2
Change Scanner Assy.
—
—
—
3
Change PWB-C.
—
—
—