FrameMaker Ver.5.5E(PC) CF1501/CF2001 DIS/REASSEMBLY, ADJUSTMENT
00.12.25
D-92
Adjustment Instructions
If there is a gap between the 2nd/3rd Mirrors Carriage Assy and the Scanner Positioning
Jig at the front, turn the adjusting screw clockwise.
If there is a gap between the 2nd/3rd Mirrors Carriage Assy and the Scanner Positioning
Jig in the rear, turn the adjusting screw counterclockwise.
4. Lightly press the 2nd/3rd Mirrors Carriage Assy up against the Scanner Positioning Jigs
and make sure there is no gap.
5. Tighten one screw to secure the adjusting plate in position.