FrameMaker Ver.5.5E(PC) CF1501/CF2001 DIS/REASSEMBLY, ADJUSTMENT
00.12.25
D-59
(38) Removal of the 2nd Image Transfer Pressure Position Sensor
1. Open the Right Door.
2. Remove the 2nd Image Transfer Roller.
☞
D-48 (steps 1 through 3)
(39) Removal of the Synchronizing Roller Sensor
1. Open the Right Door.
2. Remove the 2nd Image Transfer Roller.
☞
D-48 (steps 1 through 3)
(40) Removal of the OHP Detecting Sensor
3. Unplug one connector.
4. Remove one screw and the 2nd Image Transfer
Pressure Position Sensor.
4004D151AA
3. Unplug one connector.
4. Remove two screws and the Synchronizing
Roller Sensor.
4004D152AA
1. Open the Right Door.
2. Remove the Paper Dust Remover Unit.
4004D153AA
3. Remove the 2nd Image Transfer Roller.
☞
D-48 (steps 1 through 3)
4. Unplug one connector.
5. Remove the sensor fixing bracket and OHP
Detecting Sensor.
4004D154AA