Copier Interior Cooling Mechanism
(1)
IR Section Cooling Mechanism
• Fan motors draw air from the outside into the inside of the copier to cool the IR section
(Original Glass, CCD Sensor, Image Processing Board, etc.).
(2)
Fusing Section Cooling Mechanism
• Fan motors draw air from the area around the Fusing Unit to the outside to prevent the
copier interior temperature from running high.
Controlled Part
Control Signal
Energized
Deenergized WIRING DIAGRAM
M2
PJ2C-4B
H
L
20-I
M3
PJ6C-4
H
L
20-H
M4
PJ6C-7
H
L
20-H
Controlled Part
Control Signal
Full Speed
Half Speed
WIRING DIAGRAM
M23
PJ14I-11A
H
L
2-G
M24
PJ14I-1A
H
L
2-F
4004M054AA
Original Glass Cooling Fan Motor (M2)
IR Cooling Fan Motor 1 (M3)
IR Cooling Fan Motor 2 (M4)
4004M054AA
Fusing Cooling Fan Motor 2 (M24)