4-11
4
2
7
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill the cap with the cleaning solution just before
the solution overflows from the cap.
8
Close the right maintenance cover,
and press the
key.
• The nozzles are washed.
• When the nozzles have been completely washed,
the head moves onto the platen.
9
Suction the cleaning solution into a
syringe and squirt about three syringes
worth of solution into each cap.
10
Close the right side maintenance cover
and press the
key.
• After the idle absorbing operation has been
performed for 30 seconds, the screen returns to
step2.
• Until washing liquid is filled, [Fill the liquid.] is
displayed on the screen.