Section 6 - Storage
90-8M0053363
eng
NOVEMBER 2010
Page 125
3. To properly vent the cooling system, remove the blue drain plug from the side of the thermostat housing within 30 seconds.
a -
Blue drain plug location
4. Remove the two blue drain plugs from the seawater pickup pump (front, starboard side).
a -
Blue drain plugs
5. Verify that water is draining from each opening.
6. Allow the system to drain for a minimum of five minutes. We recommend leaving the drain system open while transporting
the boat or performing other maintenance to ensure that all water is drained.
7. Crank the engine over slightly with starter motor to purge any water trapped in the seawater pickup pump. Do not allow the
engine to start.
8. Before launching the boat or starting the engine, close the drain system by installing the four blue drain plugs.
9. Open the seacock, if equipped, or unplug and reconnect the water inlet hose prior to operating the engine.
Boat out of the Water
NOTE: Use this procedure if your engine is not equipped with an air‑actuated single‑point drain system or if the single‑point drain
system fails.
1. Place the boat on a level surface to ensure complete draining of the system.
2. Remove three blue drain plugs: one from the distribution housing (lower front, port side) and two from the seawater pickup
pump (front, starboard side).
a -
Blue drain plug
3. Verify that water is draining from each opening.
4. Allow the system to drain for a minimum of five minutes. We recommend leaving the drain system open while transporting
the boat or performing other maintenance to ensure that all water is drained.
5. Crank the engine over slightly with starter motor to purge any water trapped in the seawater pickup pump. Do not allow the
engine to start.
6. Before launching the boat or starting the engine, close the drain system by installing the three blue drain plugs.
a
6139
a
6140
a
a
6142