EXTender
TM
7000 Installation Guide
Page 46
9.
Set the following parameters specified by your service provider. If not, leave these values at the default
setting:
Table 4: LMI T1 Parameters
10. Set the PVC parameters.
Setting the Frame Relay PVC Parameters
1.
Use the arrow keys to access the following PVC_Setup menu.
MI Path
Configuration->Connect->T1/Frame_Relay->PVC Setup
Figure 3-28: T1/PVC Setup Menu
2.
Press the
→
key to access the PVC parameters screen.
Figure 3-29: PVC_1
3.
Set the Voice PVC
Supported Service
parameter for the EXTender link to
RVP_over_Frame_Relay
.
4.
Set the
DLCI
(Data Link Connection Identifier) for this PVC (16 - 1007). This number is given to you by
your service provider. The DLCI field defaults to blank and is cleared automatically if you set the PVC
type to "Not In Use."
Field
Definition
Default
Value
n391
Full Status Polling Cycles - the number of status inquiries between
each full status report.
6
n392
Error Threshold number
3
n393
Monitored Events Count - the number of status messages that are
tracked to determine if more than n392 errors have been detected.
4
t391
Link Integrity Verification Timer - Time to wait between sending each
status inquiry message.
10