EXTender
TM
7000 Installation Guide
Page 30
Connect Parameters - Serial RVP (RVP_Direct) via WAN
The EXTender utilizes a direct serial connection to provide remote user connectivity. This means that the
WAN port is plugged directly into a network device. The WAN port (WAN 1 or WAN 2) that is used as the
main or “primary” port must be identified on the RVP Direct menu.
1.
Access the Connect Menu using the following MI path:
MI Path
Configuration->Connect
The following menu appears:
Figure 3-7: Serial RVP via WAN Configuration - RVP_Direct Menu
2.
If necessary, use the
→
key to access the
Type
parameter. Set this parameter to
RVP_Direct
.
3.
Use the arrow keys to access the RVP Direct menu.
4.
Set the
Primary Interface
parameter to WAN_1. This is the main WAN port that connects the Remote
unit to the network device.
5.
Press the
→
key to scroll through the choices.
6.
Press the
↓
key to the
Secondary Interface
parameter. This identifies the secondary WAN port.
Note: This parameter is normally set to
None
.
7.
Press the
←
key to accept changes and go back to the Configuration Menu
.
8.
Press the
↓
key to the
Save
option, and press
Enter
.