The slide gate is sticking slightly. With the hopper empty and air disconnected, move
the slide manually to see that it moves freely. If material does not flow easily a bridge
breaker may be required.
8.
Load Cell weight readings are not holding steady. They vary as much as 100 grams
from second to second.
Static induced poor grounding of load cells. See Wiring Considerations.
If TARE weights are not steady, something may be physically interfering with free
movement of the weigh bin and load cells.
9.
At the end of each cycle the MIX MOTOR runs for a fraction of a second only.
The MIX MOTOR pulls a heavy amp load on start up. If the power supply is not
adequate (like when using an extension cord), the voltage will drop so low that the
computer will reset and the mix motor signal will shut off. The display will show this by
restarting as if power was just turned on. Provide a better supply of power; remove
extension cord or use larger gage wire.
Summary of Contents for FLEXBUS Lite
Page 6: ...6...
Page 10: ...10 Blender Parts Key...
Page 13: ...13...
Page 100: ...100 Technical Drawings...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112 FCA INSTALLATIONDIAGRAM...
Page 113: ...113 WSB 4088 IO wiring diagram 120V...
Page 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Page 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Page 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Page 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Page 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Page 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Page 120: ...120...
Page 138: ...138 Flexbus Lite Wiring Diagrams...
Page 139: ...139...
Page 140: ...140 Flexbus Lite Component Map...