34
Micro Pulse Instructions
This section contains Micro Pulse information for a few selected models.
MICRO PULSE
Micro Pulse valves are available on models:
WSB MB
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 122 / WSB 140m2
with optional SLIDE GATE MICRO PULSE valves.
WSB 131 / WSB 140m1
with optional SLIDE GATE MICRO PULSE valves.
WSB 140Rm1 / WSB 140Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 240Rm1 / WSB 240Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
WSB 440Rm1 / WSB 440Rm2
with optional VERTICAL VALVE MICRO PULSE valves.
These models may use our "MICRO PULSE" metering system for Color and Additive components.
PULSED OUTPUT parameters control the on/off timing, or pulsing, of the valves. The controlling
parameters are the "PO Pulsed output / timing" component settings.
When set to 00000, normal slide gate operation occurs. When set to a value, such as 00101, power will
pulse ON then OFF, at 1/10 second time intervals each way. This ON/OFF cycling will repeat for the entire
dispense time.
When using a MICRO PULSE valve, you must set the related PO parameter to 00101.
If overall blender throughput is too low, you may increase the metering rate of each Micro Pulse device by
adjusting the cylinder airflow control valves for higher flow rate. This causes more rapid movement of the
cylinder, ejecting more pellets per pulse. The drawback is noisy operation.
We recommend air flow be adjusted for quiet operation, but assuring full valve movement per on/off cycle.
We have already done this. No further adjustment should be necessary.
The approximate correct airflow adjustments are:
At nose of cylinder, 1.5 full turns out from full closed.
At rear of cylinder, 2.5 full turns out from full closed.
MICRO BLENDER slant valves, adjust by sound.
On fixed hoppers with horizontal micro pulse valves, CLEAN OUT of the hopper can be accomplished by
opening the "clean out" port provided under the valve. Turn to one side to allow material to drain.
MICRO PULSE - ACCURACY
All MICRO PULSE valves are more accurate if the associated PT parameter is set to 00090. Read PT
parameter in the PARAMETER section. Use Options / Special Functions / Operating Options / Progressive
Metering, for improved accuracy so long as the additional time necessary for Progressive Metering exists.
Read about more about Progressive Metering in the Controller Functions section.
Summary of Contents for FLEXBUS Lite
Page 6: ...6...
Page 10: ...10 Blender Parts Key...
Page 13: ...13...
Page 100: ...100 Technical Drawings...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112 FCA INSTALLATIONDIAGRAM...
Page 113: ...113 WSB 4088 IO wiring diagram 120V...
Page 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Page 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Page 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Page 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Page 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Page 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Page 120: ...120...
Page 138: ...138 Flexbus Lite Wiring Diagrams...
Page 139: ...139...
Page 140: ...140 Flexbus Lite Component Map...