45
Dispense Station
In Dispense Station Mode, material is dispensed up to a target weight and then the Dispense
Station stops and alarms. Dispense Station is enabled under System Configuration, Mode of
Operation.
When in Dispense Station mode, a button labeled "Dispense Station" will be at the bottom center
of the Home Screen.
Dispense Station Screen Description:
Dispenser Target Weight - Target Dispense Weight (pounds or kilograms). This target
weight is entered using the keypad.
Current Portion - The accumulated amount of the current dispense. This value can be
cleared by touching the field and pressing CLEAR. Clearing this value during a dispense
cycle will restart the dispense.
Accumulated Total - The accumulated total amount (pounds or kilograms) of all dispenses
since last cleared. This value can be cleared by touching the field and pressing CLEAR.
Clearing this value reset the accumulated total of all dispenses back to zero.
Dispense Count - The accumulated count of all dispenses since last cleared. This value
can be cleared by touching the field and pressing CLEAR. Clearing this value reset the
Dispense Count total back to zero.
Dispense Station Operation:
1. Press the Dispense Station button to access the Dispense Station Screen.
2. Set a Dispense Target Weight using the keypad (pounds or kilograms depending on Setup
preferences).
3. Press the Alarm button to toggle between End of Dispense Alarm
ON or OFF.
4. Press Start on the Dispense Station screen or the Home Screen to start the Dispense.
The screen will switch to the Home Screen as the Dispense Station weighs and dispenses
material. You can return to the Dispense Station screen to observe the progress.
5. When the dispense target as achieved the Dispense will stop. The Alarm will sound if the
End of Dispense Alarm is ON.
6. To restart the next dispense press the Start button located on either Dispense Station
screen or the Home Screen.
Automation of the Dispense Start
Level sensor input can be used to automate a start or restart of a dispense. This can be done by
supplying a contact closure between the small outer pin and the center pin of the level sensor
connector.
Since the Mix Motor is not used for a Dispense Station, the output is used to signal the end of a
dispense by supplying 110v output on the Mix Motor connector at the completion of a Dispense.
When the next Dispense is started Mix Motor voltage returns to zero.
Summary of Contents for FLEXBUS Lite
Page 6: ...6...
Page 10: ...10 Blender Parts Key...
Page 13: ...13...
Page 100: ...100 Technical Drawings...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112 FCA INSTALLATIONDIAGRAM...
Page 113: ...113 WSB 4088 IO wiring diagram 120V...
Page 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Page 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Page 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Page 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Page 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Page 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Page 120: ...120...
Page 138: ...138 Flexbus Lite Wiring Diagrams...
Page 139: ...139...
Page 140: ...140 Flexbus Lite Component Map...