ADDITIVES third:
The ADDITIVE dispenses occur last in the sequence. Each dispense must meet
requirements set by internal parameters.
MATERIAL RUNS OUT:
If any material runs out or is not enough to meet criteria set by parameters then the
process will NOT CONTINUE past this component. RETRIES of this dispense will
occur indefinitely until the full dispense occurs or the STOP button is pressed
followed by the ABORT button. The ALARM will sound after 4 retries (set by AL
parameter). See Component Parameters, AL parameter for the ALARM parameters.
If ALARM Occurs:
More than four retries of any single component will cause the Component Alarm and
activate the strobe light, audible alarm, and multiple on-screen alarm alerts. Every
alarm also logs to the Alarm Log. The component that is causing the alarm will
continue to retry the dispense. To continue with the dispense sequence, the
requirements of the dispense must be satisfied or the dispense aborted with the
Abort button.
WEIGH BIN dump:
After all dispenses the weigh bin is emptied by the final dump of the weigh bin into
the mixing chamber. The dump valve remains open for four seconds. (DTI
parameter)
SENSOR covered:
While the sensor is covered, the dump valve remains open to ensure the weigh bin
empties completely. Dispensing stops. The dump valve will remain open for as long
as the sensor is covered. This will be until the next cycle begins.
FLOW CONTROL Valve: (optional)
The Flow Control Valve under the mix chamber will stay closed for 6 seconds (FCV
parameter) immediately following a dispense into the mix chamber. The rest of the
time it opens when the sensor is covered, and closes when the sensor has been
uncovered for at least two full seconds (based on DLY parameter).
Summary of Contents for FLEXBUS Lite
Page 6: ...6...
Page 10: ...10 Blender Parts Key...
Page 13: ...13...
Page 100: ...100 Technical Drawings...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112 FCA INSTALLATIONDIAGRAM...
Page 113: ...113 WSB 4088 IO wiring diagram 120V...
Page 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Page 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Page 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Page 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Page 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Page 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Page 120: ...120...
Page 138: ...138 Flexbus Lite Wiring Diagrams...
Page 139: ...139...
Page 140: ...140 Flexbus Lite Component Map...