M A G U I R E P R O D U C T S , I N C .
50
W E I G H S C A L E B L E N D E R
Controller Keypad
– Summary Description
Detailed explanations are given on the pages that follow.
AUTOMATIC OPERATION MODE
: (normal operation on power up)
VIEW
View Data: date, time, cycles, and each component weight.
Press VIEW, to print data.
RCP
Enter and retrieve stored RECIPES.
BTCH
View BATCH data: Target Weight, Current Portion, and
Accumulated Total, and Batch Count. CE = clear displayed field.
FAST
Run rapid FAST cycles after a normal weighed cycle.
TAG
Tag Work Order and Operator numbers to all reports.
EXIT
Press to EXIT all sequences from ALL MODES.
SET
Press to review or change settings.
CE
Press to display "raw signal" weight readout for 3 seconds.
MANUAL OR PROGRAM MODE
: Press: ; then (11111) or your own 5 digit password.
OPER
Operate all devices manually; open and close valves.
TIME
Operate devices for a selected time period.
CAL
Operate devices to learn rate.
Above keys use 1 through 9, A, B, C, DUMP, MIX, HOLD, ALARM.
ZERO
Zero the tare weight with the bin empty.
FULL
Using known weights, enter gram weight to calibrate load cells.
00
Clear DATA fields.
99
Set flag to enable weight calibration of load cells.
PROGRAM MODE ONLY
: Press: ; then (22222) or your own password.
SET
Enter settings if access in Automatic mode has been locked out.
PARA
View or change system parameters.
Press PARA for next in list, "*" for previous, SET for next table, VIEW for previous table.
STAR FUNCTIONS:
Press and two numbers for the following functions:
02
Extrusion and Yield Control.
67
Modbus Enable / Disable.
03
3-digit (xx.x) or 4-digit (xx.xx) settings.
71
Color percent of blend.
04
Simulate FOUR software.
72
Additive percent of blend.
05
Inhibit totals clearing.
74
Stop, alarm MAX wt exceeded.
08
Blend Mode: % Total or % Natural.
75
Alarm on weight drop.
11
Date and Time adjustment.
77
Print parameters.
12
Move table from ROM to RAM.
78
Change program mode PASSWORD.
14
Set Material Types
82
Precision Ratioing.
18
Language Selection
83
Progressive Metering
22
LIW Model Selection
86
Backdoor Password
23
Move from RAM to EEPROM.
87
VOLUMETRIC operation.
25
ROM OK flag, "CE" to clear.
88
Print display readout.
32
Move from EEPROM to RAM.
89
Select pounds, kilos.
44
End cycle - bin full.
93
Update WSB software from USB drive
45
Change MANUAL mode password.
94
Update WSB Net software from USB drive
47
Totalizer flag.
95
Select COM port Baud Rate
48
Dispense range xx.x to xxx.
97
USBC Driver version display, update, verify
52
Double dump weigh bin.
98
Display raw weight number.
54
Print cycle information.
99
Enables Weight Calibration of the Load Cells
57
Alternate Liquid Color
00
Clear All Data Fields.
66
WSB I.D. number (1-255).
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...