M A G U I R E P R O D U C T S , I N C .
27
W E I G H S C A L E B L E N D E R
FULL WEIGHT CALIBRATION
The full weight calibration must be performed immediately after a zero calibration. While still in program
mode, place the calibration weight into the weigh bin. Use the chart below for the calibration weight required
for your model WSB blender.
Model
Calibration Weight
Enter this value (use your exact value)
Micro Blender (MB,MB1,MB2)
400.0 grams
04000
Tenths of grams
100 Series (140,140R,140MP,160)
1000.0 grams
10000
Tenths of grams
200 Series (220,240,240R,260)
2000.0 grams
20000
Tenths of grams
400 Series (420,440,440R,460)
4000 grams
04000
Whole grams
900 Series (940,950,960)
9000 grams
09000
Whole grams
1800 Series (1840,1850,1860)
18000 grams
18000
Whole grams
2400 Series (2400)
24000 grams
24000
Whole grams
3000 Series (2400)
30000 grams
30000
Whole grams
Press
Display will say:
WSB CELL FULL
ENTER WEIGHT: _ _ _ _ _ (5 digits)
Enter the gram value of your calibration weight at this time.
The display will then say:
PROGRAM (calibrated weight value)
Full Weight Calibration is complete. Press * 99 and then * twice to DISABLE Calibration Mode.
Press
Display will say:
CALIBRATION MODE DISABLED
Press
Display will say:
CALIBRATION MODE DISABLED
Press
Display will say:
MODE=BLEND
WAITING
Display will show the new calibrated weight value. Remove the
weight from Weigh Bin. The display should go back to displaying
0.0 g. Actual displayed weights may be +/- a few grams.
After a FULL weight calibration, if the display says BAD CELL, the controller is receiving a raw weight reading
from the load cells outside of the expected range. Verify the weigh bin is free to move and that the gram
weigh entered is correct. Verify the correct model is selected. BAD CELL may also indicate the load cells are
bad.
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...