M A G U I R E P R O D U C T S , I N C .
107
W E I G H S C A L E B L E N D E R
ZERO TARE ALARM
(former: DUMP ALARM)
ALARM CODE:15
Problem: Load Cells outside of acceptable
Calibration.
Weigh bin empty weigh above tare high upper limit (TH parameter)
or below tare lower limit (TL parameter). If above TH (upper limit)
weigh bin dump valve opens and closes repeatedly. Possible
causes:
There is material in the weigh bin that will not dump out.
The dump flap may be stuck.
The load cells are hung up or obstructed.
The load cells are out of calibration.
Solution:
Clear material jam, check dump valve for free movement,
Check that weigh bin and load cells are free from contact with door
and back of enclosure, verify weigh bin is installed correctly. If
weigh bin is empty and weight reading on-screen is above TH
parameter or below TL parameter then recalibration load cells. See
Load Cell Zero and Full Weight Calibration on page 26.
OVER WEIGHT ALARM
ALARM CODE:20
Problem: Over Dispense triggered by Alarm
Parameter
First three digits of the component specific AL parameter (
000
00)
are used to STOP and ALARM the blender if an over dispense
occurs by a specified number of grams or percent.
Grams:
enter
001 to 499 in the first three digits.
Percent:
enter the number
“5” in
the first digit. When percent is enabled, the 2
nd
and 3
rd
digits are the
percent (01
– 99). In the first digit of the _AL parameter, 6 – 9 are
invalid digits.
Solution:
Determine
cause of over dispense.
WAIT FOR RECIPE ALARM
ALARM CODE:21
Problem: Recipe Request option did not receive a
recipe within the 2-minute timeout period.
When enabled the Recipe Request option uses the Recipe Number
Tag to request a recipe over communications. If the recipe number
is changed to a value between 100 - 65535, the 2-minute Recipe
Request timer starts and monitors for a change in the recipe. If a
recipe is not received within the timeout period, this alarm sounds.
Solution:
Check Recipe number, check status of communications.
WEIGHT DROP ALARM
ALARM CODE:22
Problem: Weigh Bin loosing weight during a cycle.
This alarm is triggered by a loss of more than 20, 40,or 80 grams
(model dependent) during a dispense cycle. This serves to detect
and report a weigh bin problem, such as material leaking from the
bottom of the bin. See WDD parameter, Weight Differential Detect.
Solution:
Examine weigh bin for issues with material retention such
as weigh bin flap closure problems, material jam, angel hair causing
leak, low air pressure, damage to weigh bin or obstruction to weigh
bin closing.
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...