M A G U I R E P R O D U C T S , I N C .
37
W E I G H S C A L E B L E N D E R
Normal Operating Sequence - Each Cycle
When the sensor is uncovered, the cycle begins. The target weight of a complete batch is 18000,
9000, 4000, 2000, 1000, or 400 grams.
REGRINDS are dispensed first, in their order of size, largest dispense first. After all the Regrind
dispenses, the space remaining in the weigh bin is determined.
NATURALS are dispensed second, in their order of size, each at the correct ratio to the others.
These dispenses are calculated to fill the bin leaving just enough space for the Additive dispenses.
After all Natural dispense are complete the exact weight of all of the NATURALS is determined
and, based on this actual dispense weight, the Additive dispenses are now calculated.
ADDITIVES are dispensed last. These dispenses are calculated as a percentage of all the
NATURAL components only.
If any dispense fails to reach the requested weight, the process does NOT CONTINUE. The
ALARM Strobe light flashes, the Beeper sounds, and the system continues to retry the dispense
until the problem is remedied.
The total batch is then dropped into the mixing chamber for blending before entering the throat of
the process machine.
Special Features
– TAG, Recipe Database, FAST, Batch
To use one of these SPECIAL FEATURES, read about it first. The KEYSTROKE sequence required is given at the end of this
section.
Function:
Key:
Description:
TAG
To
TAG
all material usage data with Work Order or Employee numbers for better tracking of
material used, read: KEYPAD, TAG key, and set 2nd digit in the FLG parameter to 1.
RECIPES
To store
RECIPES
using the RECIPE storage feature, read: KEYPAD, RECIPE key, and set 3rd
digit in the FLG parameter to 1.
FAST
To increase throughput, using the
FAST
key, read: KEYPAD, FAST key, and set 4th digit in the
FLG parameter to 1.
BATCH
To blend a preset
BATCH
amount of material and then stop, read: KEYPAD, BATCH key, and
set 5th digit in the FLG parameter to 1.
BATCH
,
RECIPE
,
FAST
, and
TAG
keys REQUIRE that you read: PARAMETERS, FLG parameter.
SETTINGS
To use a lower percentage than 00.1 percent, read: PARAMETERS, _XT parameter.
MIXING
To change the
MIXER RUN TIME
, read: PARAMETERS, MIX Parameter.
SETTINGS
To place
UPPER LIMITS
on settings, read: PARAMETERS, _SE Parameter.
PASSWORDS
To
LOCK OUT
others from changing the settings, read: PARAMETERS, (*78) - Changing the
Password.
ACCURACY
To
VERIFY ACCURACY
of the entire system, read: PRINTER OUTPUT and
TROUBLESHOOTING sections.
DATA
To TRACK
MATERIAL USAGE
, read: KEYPAD, VIEW DATA, and PARAMETERS, PRT
Parameter.
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...