M A G U I R E P R O D U C T S , I N C .
64
W E I G H S C A L E B L E N D E R
Volumetric Mode
Press (*,8,7) to set flag for operation in a VOLUMETRIC mode. Use the * key to toggle the flag
ENABLED or DISABLED. Press EXIT when done. When power is turned off this flag is always
reset to OFF. With this flag ENABLED (VOLUMETRIC mode), the load cells are completely
ignored. Error correction and rate recalibration does not take place. The unit functions like a
volumetric feeder without checking or correcting for errors. Since load cell readings are ignored,
this flag allows operation even if the load cells become damaged. Dispense times will be based
entirely on the WT and TI parameters.
Printout Display
Press (*,8,8) to force a printout of the display on the controller front. DATE, TIME, Machine
number, and displayed weight will print:
Date:
11/09/2006
Time:
17:22:01
Machine number:
001
Display Readout:
2000.0 g
This is useful for obtaining printed verification of load cell accuracy ISO and other international
quality program rules.
The recommended procedure is:
1. Place the unit into the Program mode.
2. Press *88 for printout of empty bin TARE weight.
3. Place a KNOWN CERTIFIED WEIGHT into the weight bin.
4. Press *88 again for printout with the weight added.
5.
The different between the two weight printouts should equal the KNOWN CERTIFIED
WEIGHT.
Select Weight Unit
Press (*,8,9) to select the desired weight unit (GRAMS, KILOGRAMS, OUNCES, POUNDS) for
readout of data. For the U.S.A. systems are supplied with POUND readout selected.
KILOGRAMS are preferred for nearly all countries outside the U.S.A. GRAM or OUNCE
readouts are appropriate only for very short runs or short demonstrations. Use the * key to
toggle through the four possible selections. Press EXIT when the weight unit you want is
displayed.
Update Controller Software From USB Drive
Press (*,9,3) to initiate a software update from the USB Drive. Pressing *,9,3 will cause the
controller to search the USB drive for a folder named
maguire
and 3 files within the folder
maguire
named:
UPDATER3.BIN
,
912WFxxxxx.crc
, and
912WFxxxxx.s28
. If more than one
.s28 file exists in the maguire folder, the controller will prompt you to select the version. Press
the * key to toggle between versions. Press the CE key to select the version you want to
upload. The controller will then verify the file. If verification is successful the controller will
upload the new software. DO NOT turn off the controller during this process. Wait until you see
Update Complete!
Then turn off the controller and turn it back on again. The update should
take only a few minutes. Updated software is available from Maguire Products free of charge
and can be obtained by calling our office or visiting us on the web
Update Controller NET Software From USB Drive
Press (*,9,4) to initiate a NET specific software update from the USB Drive. Pressing *,9,4 will
cause the controller to search the USB drive for a folder named
maguire
and 2 files within the
folder
maguire
named:
UPDATER.BIN
and
NETxxxxx.BIN
. If more than one .BIN file exists in
the maguire folder, the controller will prompt you to select the version. Press the * key to toggle
between versions. Press the CE key to select the version you want to upload. The controller
will then verify the file. If verification is successful the controller will upload the new software.
DO NOT turn off the controller during this process. Wait until you see
Update Complete!
Then
turn off the controller and turn it back on again. The update should take only a few minutes.
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...