IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-44
Weight Measurement
The IMPULSE
®
•G+ & VG+ Series 4 includes a Weight Calculation function that can be used in
hoisting applications. The weight measurement calculation is based on motor torque at a constant
speed. The drive must pause the acceleration, wait for the torque to stabilize, and then perform the
weight calculation based on the system tare values. The function takes a reading one time per lift
(Raise Run command) when C10-01 = 1 (Automatic), or it can be configured to take a reading at any
speed with a Multi-Function Input when C10-02 = 1 (Manual). The calculated weight can be
displayed on the keypad of the hoist drive.
NOTE:
Weight Calculations will be more consistent when a weight measurement is calculated
at the same speed every time. Example: C10-01 = 1, weight measurement is always
calculated at C10-05 speed. It is important to note that after the load has been rigged,
it should be suspended and the brakes should be set on the hoist. When the next
raise command is given, the hoist is now ready to calculate the weight of the load. The
function only works in the Raising motion (Fwd Run). If extreme accuracy is required,
a load cell should be used.
The Weight Measurement function of the hoist drive has an accuracy within 5% with
VG+ drives and 10% with G+ drives of the hoist’s rated capacity.
Table 5-35: Weight Measurement Parameter Settings
Parameter Display
Function
Range
Default Model
C10-01
Load Weight
Selects method for Load Weight
measurements. Measurement is
reset at Brake Closed.
0–2
0
G+/VG+
0
Disabled
1
Auto - I/T
Enabled (VG+ Only)
2
Auto-Analog
Enabled Analog
C10-02
LW Start
LW Measurement Start
0, 1
0
G+/VG+
0
At C10-05
1
By MFDI=5C
C10-03
LW Display Hold
0, 1
0
G+/VG+
0
Hold Display
Hold until next run command
1
Hold Disp 3 Sec
C10-04*
LW Conversion
Multiplier of torque output
calculation for display. Data is
n0000, so multiplier is 10000; “n” is
decimal point.
Example: 24000 = 40.00
0–39999
0
G+/VG+
C10-05
Test Freq
Frequency at which the Weight
Measurement will occur.
0–E01-04 Hz
6
G+/VG+
C10-06*
Unit Displayed
Selects the units of measurement
being displayed.
0–4
4
G+/VG+
0
Tons
1
Pounds
2
Kilograms
3
Metric Tons
4
Percent Load
C10-07
Holding Time
Time for holding output frequency
to measure weight.
0.0–2.55 sec
1.00
G+/VG+
C10-09
Full Load Torque
Percentage of Torque output that
is considered full load.
0.0–200.0%
100.0
VG+
C10-10
No Load Torque
Percentage of Torque output that
is considered no load.
0.0–200.0%
20.0
VG+
* Used for keypad display; consult factory for assistance.
Summary of Contents for Impulse G+ series 4
Page 2: ......
Page 6: ...IMPULSE G VG Series 4 Instruction Manual February 2017 iv This page intentionally left blank...
Page 12: ...IMPULSE G VG Series 4 Instruction Manual February 2017 This page intentionally left blank...
Page 13: ...C h a p t e r 1 Introduction...
Page 14: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 2 This page intentionally left blank...
Page 26: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 14 This page intentionally left blank...
Page 27: ...C h a p t e r 2 Installation...
Page 28: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 2 This page intentionally left blank...
Page 40: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 14 This page intentionally left blank...
Page 41: ...C h a p t e r 3 Wiring...
Page 42: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 2 This page intentionally left blank...
Page 66: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 26 This page intentionally left blank...
Page 67: ...C h a p t e r 4 Getting Started...
Page 68: ...IMPULSE G VG Series 4 Instruction Manual February 2017 4 2 This page intentionally left blank...
Page 87: ...C h a p t e r 5 Programming Advanced Features...
Page 88: ...IMPULSE G VG Series 4 Instruction Manual February 2017 5 2 This page intentionally left blank...
Page 223: ...C h a p t e r 6 Troubleshooting...
Page 224: ...IMPULSE G VG Series 4 Instruction Manual February 2017 6 2 This page intentionally left blank...
Page 255: ...a p p e n d i x A IMPULSE G VG Series 4 Parameter Listing...
Page 256: ...IMPULSE G VG Series 4 Instruction Manual February 2017 A 2 This page intentionally left blank...