Copy Function Related Faults
Tasks, Errors, and Troubleshooting
The table below lists the messages and errors that may appear when using the Copy function.
When executing the tasks offered by the Copy function, the operator will indicate the task being
performed. When an error occurs, a code appears on the operator to indicate the error. Note that
errors related to the Copy function do not trigger a multifunction output terminal that has been set up
to close when a fault or alarm occurs. To clear an error, simply press any key on the operator and the
error display will disappear.
Table 6-7 lists the corrective action that can be taken when an error occurs.
NOTE:
1. Whenever using the copy function, the drive should be fully stopped.
2. The drive will not accept a Run command while the Copy function is being executed.
3. Parameters can only be saved to a drive when the voltage class, capacity, control
method, and software version match.
Table 6-7: Copy Function Task and Error Displays
oPE07
A1-A3
Multi-function Analog
Input Selection Error.
• At least two analog
input terminals are set
to the same function.
• Analog input terminal
and pulse train input
are set to the same
function.
• Adjust H03-02,
H03-06, and H03-10
settings so functions
no longer conflict.
Error
Card
Fault or Indicator
Name/Description
Cause
Possible Solution
Fault Display
Fault or Indicator Name/Description
Corrective Action
CPEr
Control Method Mismatch.
Control method
of the parameters to be loaded onto the drive
and the control method set to the drive do not
match.
• Verify the control method for the parameters
to be loaded onto the drive and the control
method on the drive to which those
parameters will be written.
• Set the same control method using
parameter A01-02 and retry.
CPyE
Error Writing Data.
Failed writing
parameters.
Attempt to write parameters again.
CSEr
Copy Unit Error.
Hardware fault.
Replace the operator or the USB Copy Unit.
iFEr
Communication Error.
• A communication error occurred between
the drive and the operator or the USB copy
unit.
• A non-compatible cable is being used to
connect the USB Copy Unit and the drive.
• Check the cable connection.
• Use the cable originally packaged with the
USB Copy Unit.
Summary of Contents for Impulse G+ series 4
Page 2: ......
Page 6: ...IMPULSE G VG Series 4 Instruction Manual February 2017 iv This page intentionally left blank...
Page 12: ...IMPULSE G VG Series 4 Instruction Manual February 2017 This page intentionally left blank...
Page 13: ...C h a p t e r 1 Introduction...
Page 14: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 2 This page intentionally left blank...
Page 26: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 14 This page intentionally left blank...
Page 27: ...C h a p t e r 2 Installation...
Page 28: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 2 This page intentionally left blank...
Page 40: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 14 This page intentionally left blank...
Page 41: ...C h a p t e r 3 Wiring...
Page 42: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 2 This page intentionally left blank...
Page 66: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 26 This page intentionally left blank...
Page 67: ...C h a p t e r 4 Getting Started...
Page 68: ...IMPULSE G VG Series 4 Instruction Manual February 2017 4 2 This page intentionally left blank...
Page 87: ...C h a p t e r 5 Programming Advanced Features...
Page 88: ...IMPULSE G VG Series 4 Instruction Manual February 2017 5 2 This page intentionally left blank...
Page 223: ...C h a p t e r 6 Troubleshooting...
Page 224: ...IMPULSE G VG Series 4 Instruction Manual February 2017 6 2 This page intentionally left blank...
Page 255: ...a p p e n d i x A IMPULSE G VG Series 4 Parameter Listing...
Page 256: ...IMPULSE G VG Series 4 Instruction Manual February 2017 A 2 This page intentionally left blank...