Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller SFP (0x2, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_TRANSCEIVER_MODULE ( failedGbic.html )
MEL_EV_ICM_ENTERING_INVALID_SYSTEM_CONFIG - 0x2900
This event occurs when: The system enters an invalid configuration state as well as every 24 hours if the
system remains in that state. When the system is in an invalid configuration state, no configuration changes
are allowed -- no new volumes can be created, no new snapshots, no changes of any kind. IO can still be
performed to existing user data. Use the recovery guru to correct the invalid configuration state.
Event Name - Entering Invalid System Configuration
Event description: Entering invalid system configuration
Event Group - ICM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FLASH_CACHE_FAILED_CACHE_SIZE_MISMATCH - 0x3604
This event occurs when: An SSD cache fails due to cache size mismatch on the two controllers.
Event Name - SSD Cache Failed Cache Size Mismatch
Event description: SSD cache failed due to cache size mismatch on the two controllers
Event Group - Flash Cache
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Unknown (0x0)
Event Component Type - SSD Cache (0x3, 0x8)
Event Specific Data - Optional data is not provided with this event.
.
243
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......