Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SUBMODEL_MISMATCH ( ctrlMismatch.html )
MEL_EV_ESM_TYPE_MISMATCH - 0x2849
This event occurs when: A controller detects an IOM (ESM) hardware mismatch in an enclosure in the
storage array.
Event Name - ESM Type Mismatch
Event description: IOM (ESM) Hardware mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ESM_HARDWARE_MISMATCH ( ESMHwMismatch.html )
MEL_EV_LINK_SPEED_SWITCH_CHANGE - 0x284B
This event occurs when: A controller detects that an ESM hardware mismatch condition has been cleared.
Event Name - Link Speed Switch Change
Event description: Link Speed (data rate) switch position has changed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_REDUNDANT_PS_REQUIRED - 0x284E
This event occurs when: A controller discovers a fan-only CRU in an enclosure that requires, for redundancy
reasons, the power supply/fan combination CRU. This event will only be logged once when the condition
occurs.
.
237
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......