Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DRIVE_FAILED
RecoveryFailureType - REC_FAILED_DRIVE ( failedDrive.html )
MEL_EV_DRIVE_IN_VG_OR_HOT_SPARE_REMOVED - 0x226D
This event occurs when: A drive that was assigned to a volume group or a hot spare drive that is in use has
been removed.
Event Name - Drive In Volume Group Or Hot Spare In Use Removed
Event description: Assigned drive or hot spare-in use drive removed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_HOTSPARE_DRIVE_MISSING ( missingHotSpare.html )
MEL_EV_SSD_AT_END_OF_LIFE - 0x226E
This event occurs when: It is recommended that the customer schedule replacing the SSD immediately or
risk having the drive fail.
Event Name - SSD At End Of Life
Event description: Solid state disk drive at end of life
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
218
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......