Event description: Communication to remote volume down
Event Group - Remote Volume
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REMOTE_NO_ARRAY ( remoteNoArray.html )
MEL_EV_RMTVOL_WWN_CHANGE_FAILED - 0x6505
This event occurs when: This error occurs if an array detects during start-up processing that its WWN
changed. When the firmware detects this name change, it attempts to notify any remote array that had
previously been participating in a mirroring relationship. This event has been replaced with 0x6507.
Event Name - RMTVOL Node WWN Changed Failed
Event description: Failed to communicate storage array's world-wide name
Event Group - Remote Volume
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_RMTVOL_NODE_WWN_CHANGED
RecoveryFailureType - REC_REMOTE_WWN_CHANGE_FAILED ( wwnChangeFailed.html )
MEL_EV_VOLCOPY_FAILED - 0x6600
This event occurs when: A volume copy operation fails due to one of the following reasons: Read error on
source volume, Write error on target volume, Configuration change resulting in a feature compatibility
violation (e.g. Role Change of a Remote Mirror).
Event Name - VOLCOPY Failed
Event description: Volume copy operation failed
Event Group - Volume Copy
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
.
261
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......