Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_TRAY_REDUNDANCY_LOSS - 0x282B
This event occurs when: A drive tray path fails.
Event Name - Tray Redundancy Loss
Event description: Drive tray path redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_LOST_REDUNDANCY_TRAY ( noRedundancyTray.html )
MEL_EV_DRIVE_REDUNDANCY_LOSS - 0x282D
This event occurs when: An array determines that a loss of drive path redundancy is a persistent condition.
Event Name - Drive Redundancy Loss
Event description: Drive path redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_DRIVE_BYPASSED_SINGLE_PORT ( bypassedDrive.html ), REC_LOST_
REDUNDANCY_DRIVE ( noRedundancyDrive.html )
232
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......