RecoveryFailureType - N/A
MEL_EV_PERSIST_MPE - 0x2604
This event occurs when: A SOD detects that the persistent memory parity error state has been set. RPA
memory has reported a persistent error, this generally results in a lock-down.
Event Name - Persistent Memory Parity Error
Event description: Persistent controller memory parity error
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_SOD_FDE_INCONSISTENT_ARRAY_LOCK_KEY - 0x2607
This event occurs when: An inconsistent array lock key situation is detected.
Event Name - FDE Inconsistent Array Lock Key
Event description: Inconsistent security (FDE) storage array lock key
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_KEY_INCONSISTENT ( fdeInconsistentSecurityKey.html )
MEL_EV_MULTIPLE_MISMATCHED_KEY_IDS - 0x2705
This event occurs when: Multiple mismatched drive lock key ids are detected by the firmware.
Event Name - Multiple Mismatched Key Ids Found
Event description: Multiple mismatched key ids found
Event Group - Start of Day
226
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......