Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ENCLOSURE_THERMAL_SHUTDOWN ( thermal_shutdown.html )
MEL_EV_DRAWER_DEGRADED - 0x285F
This event occurs when: Either DCM on the drawer has failed, the drawer is marked as degraded. The drawer
needs to be serviced but one DCM is still operational, allowing continued IO to the drives on the drawer. If
both DCMs fail, the drawer is marked as failed.
Event Name - Drawer Degraded
Event description: A drawer in the tray has become degraded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
Event Specific Data - Optional data is provided with this event.
MEL_DCMM_DRAWER_PATH_FAIL
RecoveryFailureType - REC_DRAWER_DEGRADED ( degradedDrawer.html )
MEL_EV_DRAWER_INVALID - 0x2861
This event occurs when: An invalid drawer has been detected inside the drive enclosure.
Event Name - Drawer Invalid
Event description: A drawer has been detected that is not valid
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
.
241
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......