MEL_DATA_REDUNDANCY_MISMATCH_DETECTED
RecoveryFailureType - N/A
MEL_EV_DIFFERENT_DATA_RETURNED_ON_RETRY - 0x2047
This event occurs when: A redundancy check results in retried reads and the drive returns different data on
the retry.
Event Name - Different Data Returned On Retry
Event description: Different Data Returned On Read Retry
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DIFFERENT_DATA_RETURNED_ON_RETRY
RecoveryFailureType - N/A
MEL_EV_DATA_ALTERED_TO_CORRECT_REDUN_MISMATCH - 0x2048
This event occurs when: Data is altered due to a detected inconsistency in redundancy. The data, which was
within a redundancy group with multiple redundancy (e.g. RAID 6), was isolated, recovered, and rewritten to
the drive.
Event Name - Data Altered to Correct Redundancy Mismatch
Event description: Data altered to correct redundancy mismatch
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_REDUNDANCY_MISMATCH_DETECTED
RecoveryFailureType - N/A
MEL_EV_PI_SERVICE_MODE_ENTERED - 0x2069
This event occurs when: This event is logged when the controller has been rebooted into Service Mode
because the controller has detected excessive Data Assurance errors.
204
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......