DataPort 3 Installation Guide

Affordable removable hard drive enclosure.

Preparation for Installation

Note:

 To prevent data loss, read this manual before 

installing or operating the DataPort 3. Before touching 

any electrical equipment, ground yourself by touching 

the metal part of your computer chassis. This discharges 

static electricity and prevents any damage to your com-

puter. CRU is not responsible for static discharge damage.

Tools Required

Phillips screwdriver

Other Items that May Be Needed 

Computer Users Manual.

HDD manual (to set slave/master jumper for IDE only.)

Serial ATA cable or IDE data cable.

Frame Installation

1.  Identify the 5.25” half-height bay in which you plan 

to mount the DataPort 3 frame assembly. Remove 

any filler plates that may be present.

2.  If the drive bay requires mounting rails, install 

one on each side of the frame. The mounting rails 

should be provided with your computer system.

3.  Slide the frame into the 5.25” bay of the PC case. 

If needed, use the screws provided to secure the 

frame assembly to the PC case with the frame’s side 

mounting holes.

4.  Locate the data cable and connect it to the appropri-

ate IDE or Serial ATA connector on the frame.

5.  Locate an available 4-pin DC power cable from the 

computer power supply and plug it into the power 

receptacle on the frame.

The frame installation is now complete.

Mounting a Hard Drive in the Carrier

1.  Remove the carrier top cover. The cover of the 

DataPort 3 slides into place on the carrier without 

any screws.

2. For IDE units:

a)  Set Master/Slave jumper on drive before 

placing drive in carrier.

b) Connect the DC power cable to the drive.
c)  Connect the data cable in the carrier to the 

drive.

2a.  For Serial ATA units place the drive in the 

carrier and connect the male connector on 

the hard drive to the female connector on 

the carrier.

3.   Secure the drive in the carrier, using the four 

screws provided to mount the drive. Position the 

cables inside the carrier assembly so that they are 

completely enclosed within the carrier.

4.   Ensure that the lock of the DataPort 3 is in the 

“open” (vertical) position. Slide the carrier into the 

frame. Using thumb pressure, fully seat the carrier 

in  the frame, then lock the unit with the keylock.