Press on the tab
<Interval>
(2)
to select the tab.
Now mark in the setting field
<Interval On>
(3)
the hour- or minute block to change
the values.
With the the two
<Arrow keys>
(6)
you can increase or reduce the blocks wich are
each marked.
Now carry out the settings in the field
<Interval Off>
(4)
accordingly.
Now activate if necessary the viscosity control by clicking on the check box
(7)
. An
activated control is displayed by a
in the check box.
7.3.1.4 Interface (Encoder interface)
Under the tab
< Interfaces>
you can set the interface for the incremental encoder and
you can also switch on or off the bounce time delay. The bounce time delay is required
for working with external jobs.
Definition
„bounce time“ and „bounce time delay“:
Bounce time:
Describes the period which a signal requires after an input has been switched to
reach a defined status (0 or 1) again.
Bounce time delay:
Describes a predefined safety time. That means if an input is switched, the signal
will be only valid after this safety time.
At the LEIBINGER Printer you can switch on or off this safety time.
Bounce time delay
Advantages
Disadvantages
off
Faster change of jobs
No safety for bouncing signals
afterwards
on
High safety for bouncing
signals afterwards
Slower change of jobs
Figure 49
Bounce time delay
Time (t)
defined
status
t
Safety
defeatable)
Switching of
inputs
In
pu
t-
S
ign
al
ga
ug