User Manual Of EL7-EC** AC Servo
74
Set
Torque
Constant
speed
Deceleration
Hysteresis
Level
1st
2nd
1st
2nd
1st
Acceleration
Set
Velocity
Hysteresis
Level
1st
2nd
1st
Pr1.15
Label
Position control gain
switching mode
Mode
F
Range
0~11
Unit
—
Default
0
Index
2115h
Activation
Immediate
Set
Value
Condition
Gain switching condition
0
1
st
gain fixed
Fixed on using 1
st
gain(Pr1.00-Pr1.04)
1
2
nd
gain fixed
Fixed on using 2
nd
gain (Pr1.05-Pr1.09)
2
Reserved
3
High set torque
Switch to 2
nd
gain when set torque command absolute value
larger than (level + hysteresis)[%]
Switch to 1
st
gain when set torque command absolute value
smaller than (level + hysteresis)[%]
4
Reserved
Reserved
5
High set velocity
Valid for position and velocity control.
Switch to 2
nd
gain when set velocity command absolute value
larger than (level + hysteresis)[r/min]
Switch to 1
st
gain when set velocity command absolute value
smaller than (level-hysteresis)[r/min]