User Manual Of EL7-EC** AC Servo
161
Table 5.1 Status description
Status
Description
Initialization
starts
Driver powered on, initialization starts; Holding brake activated;
Axis disabled
Initialization done Initialization done; Parameters initialize, faultless; Axis disabled.
Ready
Parameter initialization done; Axis disabled.
Enable
Servo driver is ready to be enabled.
Running
Driver enabled, faultless
Quick stop
Quick stop activated
Fault triggered
Alarm not solved yet; Axis disabled.
Fault
Alarm solved. Waiting to switch from 402 state machine to
Initialization starts; Axis disabled.
402 state machine switching is dependent on master device controlled servo driver
control word (6040h)
CiA402 status switching
Control word 6040h
Status word 6041h
Bit1-Bit9
0
Power on Initialization
Transit automatically
0x0000
1
Initialization Faultless
Transit automatically,
Enter 13 if fault occurs
0x0250
2
Faultless-- Ready
0x0006
0x0231
3
Servo ready-- Waiting to
enable
0x0007
0x0233
4
Waiting to enable-- Running
0x000F
0x0237
5
Running Waiting to enable
0x0007
0x0233
6
Waiting to enable Ready
0x0006
0x0231
7
Ready Faultless
0x0000
0x0250
8
Running Ready
0x0006
0x0231
9
Running-- Faultless
0x0000
0x0250
10
Waiting to enable Faultless
0x0000
0x0250
11
Running-- Quick stop
0x0002
0x0217
12
Quick stop Faultless
Transit automatically
0x0250
13
Fault stop
Transit automatically
0x021F
14
Fault stop-- Fault
Transit automatically
0x0218
15
Fault Faultless
0x80
0x0250
16
Quick stop-- Running
0x0F
0x0237