User Manual Of EL7-EC** AC Servo
107
Bit
Label
Description
0
Start
1 - valid, 0 - invalid
1
Main circuit power on
1 - valid, 0 - invalid
2
Quick stop
0 - valid,1 - invalid
3
Servo running
1 - valid, 0 - invalid
4-6
Running mode related
Related to each servo running mode
7
Fault reset
Reset resettable fault alarm. Rising edge of Bit7 is
valid, bit7 remains at 1, and all other instructions are
invalid
8
Pause
For more information on how to pause in each
mode, refer to Object Dictionary 605Dh
9
No definition
Undefined
10
Reserved
Undefined
11-15
Reserved
Undefined
Index
6041h
Label
Status word
Unit
-
Structure
VAR Type
Uint 16
Access
RO
Mapping TPDO
Mode
ALL Range
0x0~
0xFF
FF
Default 0x0
Bit
Label
Description
0
Servo ready
1 - valid, 0 - invalid
1
Start
1 - valid, 0 - invalid
2
Servo running
1 - valid, 0 - invalid
3
Fault
1 - valid, 0 - invalid
4
Main circuit power on
1 - valid, 0 - invalid
5
Quick stop
0- valid, 1 - invalid
6
Servo cannot run
1 - valid, 0 - invalid
7
Warning
1 - valid, 0 - invalid
8
Reserved
Reserved
9
Remote control
1 - valid, 0 - invalid
10
Arrived at position
1 - valid, 0 - invalid
11
Internal limit valid
1 - valid, 0 - invalid
12-13
Mode related
Related to each servo operation mode
14
Reserved
Reserved
15
Origin found
1 - valid, 0 - invalid
Index
605Ah
Label
Quick stop option code
Unit
-
Structure
VAR Type
INT 16
Access
RW
Mapping -
Mode
ALL Range
0~7
Default 2
Motor stops when quick stop command is given.
PP, CSP, CSV, PV
0
:
To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1
:
Motor decelerates and stops through 6084. Status: Switch on disable, axis disabled.