User Manual Of EL7-EC** AC Servo
54
Class
Label
EtherCAT
Address
Panel
display
Activation
Valid Mode
rotational direction
selection
Velocity command input
gain
2302h
PR_302
Immediate
PV
CSV
Velocity command input
inversion
2303h
PR_303
Immediate
PV
CSV
1
st
speed of velocity
setting
2304h
PR_304
Immediate
PV
CSV
2
nd
speed of velocity
setting
2305h
PR_305
Immediate
PV
CSV
3
rd
speed of velocity
setting
2306h
PR_306
Immediate
F
4
th
speed of velocity
setting
2307h
PR_307
Immediate
F
5
th
speed of velocity
setting
2308h
PR_308
Immediate
F
6
th
speed of velocity
setting
2309h
PR_309
Immediate
F
7
th
speed of velocity
setting
2310h
PR_310
Immediate
F
8
th
speed of velocity
setting
2311h
PR_311
Immediate
F
Acceleration time
settings
2312h
PR_312
Immediate
F
Deceleration time
settings
2313h
PR_313
Immediate
PP
H
M
CSP
Sigmoid
acceleration/deceleratio
n settings
2314h
PR_314
Disable
PP
H
M
CSP
Zero speed clamp
function selection
2315h
PR_315
Immediate
PP
H
M
CSP
Zero speed clamp level
2316h
PR_316
Immediate
F
Internal/External
settings of torque
2317h
PR_317
Immediate
PV
CSV
Torque command
direction selection
2318h
PR_318
Immediate
PV
CSV
Velocity limit value in
torque mode
2321h
PR_321
Immediate
F
Torque limit value in
torque mode
2322h
PR_322
Immediate
F
Zero speed clamp static
time
2323h
PR_323
Immediate
F
[C
la
ss
3
] V
el
oci
ty
/ T
or
qu
e
co
nt
ro
l