User Manual Of EL7-EC** AC Servo
291
Error
code
Main Sub
Display: “
Er 82d”
82
d
Error description: No synchronization error
Cause
Synchronization is invalid
The status of the
error can be detected
operation
The result status
Safe operation
Solution
1. Verify if "fatal synchronization error" has occurred.
2. Verify master device synchronization settings
Error
code
Main Sub
Display: “
Er 82E”
82
E
Error description: Synchronization cycle time is too short
Cause
Master device synchronization cycle time is set to less than 125
microseconds
The status of the
error can be detected
operation
The result status
Pre-operation
Solution
Verify master device synchronization cycle time
Error
code
Main Sub
Display: “
Er 830”
83
0
Error description: Invalid Distributed Clock synchronization settings
Cause
Synchronization settings in sync mode are not valid
The status of the
error can be detected
Safe operation
The result status
Pre-operation
Solution
Verify master device synchronization settings
Error
code
Main Sub
Display: “
Er 832”
83
2
Error description: Distribution Clock phase-locked loop failure
Cause
Distribution Clock phase-locked loop setting is invalid
The status of the
error can be detected
Safe operation, operation
The result status
Safe operation
Solution
Verify master device Distribution Clock settings and network
transmission delay