User Manual Of EL7-EC** AC Servo
104
Pr6.21
Label
Trial run waiting time
Mode
F
Range
0~30000
Unit
ms
Default
300
Index
2621h
Activation
Immediate
JOG (Position control) : Waiting time after each motion
Pr6.22
Label
No. of trial run cycles
Mode
F
Range
0~32767
Unit PCS
Default
5
Index
2622h
Activation
Immediate
JOG (Position control) : No. of cycles
Pr6.25
Label
Trial run acceleration
Mode
F
Range
0~10000 Unit
ms/(1000rpm) Default
200
Index
2625h
Activation
Immediate
To set the acceleration/deceleration time for JOG command between 0 rpm to 1000 rpm
Pr6.28
Label
Velocity observer gain
Mode
F
Range
0~32767
Unit
—
Default
0
Index
2628h
Activation
Immediate
0: Default stable gain; Modifications are not recommended.
Pr6.29
Label
Velocity observer
bandwidth
Mode
F
Range
0~32767
Unit
ms
Default
0
Index
2629h
Activation
Immediate
0: Default stable
bandwidth
; Modifications are recommended.
Pr6.34
Label
Frame error window time Mode
F
Range
0~32767
Unit
ms
Default
100
Index
2634h
Activation
Immediate
To set EtherCAT data frame error detection window time
Pr6.35
Label
Frame error window
Mode
F
Range
0~32767
Unit
-
Default
50
Index
2635h
Activation
Immediate
To set EtherCAT data frame error detection window