User Manual Of EL7-EC** AC Servo
56
Class
Label
EtherCAT
Address
Panel
display
Activation
Valid Mode
Overload level setting
2512h
PR_512
Immediate
F
Overspeed level settings
2513h
PR_513
Immediate
F
I/O digital filter
2515h
PR_515
Immediate
F
Counter clearing input
mode
2517h
PR_514
Immediate
F
Position unit settings
2520h
PR_520
Disable
F
Torque limit selection
2521h
PR_521
Immediate
F
2
nd
torque limit
2522h
PR_522
Immediate
F
Positive torque warning
threshold
2523h
PR_523
Immediate
PP
H
M
CSP
Negative torque warning
threshold
2524h
PR_524
Immediate
F
LED initial status
2528h
PR_528
After restart
F
Max. command pulse
input frequency
2532h
PR_532
Immediate
F
Encoder zero position
compensation
2601h
PR_601
After restart
F
JOG trial run velocity
command
2604h
PR_604
Immediate
F
Position 3
rd
gain valid
time
2605h
PR_605
Immediate
PP
H
M
CSP
Position 3
rd
gain scale
factor
2606h
PR_606
Immediate
PP
H
M
CSP
Torque command
additional value
2607h
PR_607
Immediate
F
Positive direction torque
compensation value
2608h
PR_608
Immediate
F
Negative direction torque
compensation value
2609h
PR_609
Immediate
F
Current
response
settings
2611h
PR_611
Immediate
F
Max. time to stop after
disabling
2614h
PR_614
Immediate
F
Trial run distance
2620h
PR_620
Immediate
F
Trial run waiting time
2621h
PR_621
Immediate
F
No. of trial run cycles
2622h
PR_622
Immediate
F
Trial run acceleration
2625h
PR_625
Immediate
F
Velocity observer gain
2628h
PR_628
Immediate
F
Velocity observer
bandwidth
2629h
PR_629
Immediate
F
Frame error window time
2634h
PR_634
Immediate
F
Frame error window
2635h
PR_635
Immediate
F
[C
la
ss
6]
O
the
r
se
tti
ng
s