INSTALLINg THE CARBONATOR PUMP
1. Check water pressure and volume. Water pressure should be at least 40 lbs with
carbonator running.
2. Install carbonator pump within eight feet of cold plate and within six feet of an
electrical plug. It should be at installed at least six inches off the floor (recommend
installing on a shelf).
3. Connect liquid level control to probe using harness provided. Ensure that quick
connects are fastened tightly together.
NOTE:
Failure to connect pump platform to probe may cause the pump motor to run
continuously causing the motor to overheat. If this happens, unplug unit, wait five
minutes, and make all connections.