QUICK START UP

 CAUTION

- When connecting a DOSATRON either to the public water 
supply or to its own water source, you must respect the 
regulations in force concerning protection of the source i.e. 
backflow prevention, etc.

- Contact local authorities for requirements of backflow 
prevention.

- When installing, operating, and maintaining the DOSATRON 
water powered metering pump, keep safety considerations 
foremost. Use proper tools, protective clothings, and eye 
protection when working on the equipment and install the 
equipment with a view toward ensuring safe operation.

- Follow the instructions in the manual and take additional 
safety measures appropriate to the liquid being pumped and 
the temperature of the water that powers the DOSATRON. 
Be extremely careful in the presence of hazardous 
substances (e.g. corrosives, toxins, solvents, acids, caustic, 
flammables, etc.).

- Before applying any aggressive chemicals, please consult 
your distributor to confirm compatibility with the dosing 
pump.

 Hand tighten. No tools needed.

Congratulations on your new Dosatron.
Please read the following important information.

IMPORTANT NOTES

For complete information on the features and operations, 

refer to your manual on www.dosatron.com 

or download our DOSATRON app

or

NEED HELP ? Contact your DOSATRON distributor

for service or parts.

D8 RANGE
8 m

3

/h - 40 US GPM

 

ET283/W

arning-D8-EN-US/1

1/15

m

3

/h

This document does not form a contractual engagement on the part of Dosatron International and is for 

information only. Dosatron International reserves the right to alter product specification or appearance 

without prior notice.  

© DOSATRON INTERNATIONAL S.A.S 2012

CUSTOMER SERVICE - SERVICE CLIENTÈLE 
(NORTH & CENTRAL AMERICA) 

 
DOSATRON INTERNATIONAL INC.

2090 SUNNYDALE BLVD. CLEARWATER - FL 33765 - USA

Tel. 1-727-443-5404 / 1-800-523-8499 - Fax 1-727-447-0591
Site web: www.dosatronusa.com

www.dosatron.com

40 US GPM

DOSATRON INTERNATIONAL S.A.S. 

 

Certified QEH&S System

Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE

Tel. 33 (0)5 57 97 11 11
Fax. 33 (0)5 57 97 11 29 / 33 (0)5 57 97 10 85
[email protected] - www.dosatron.com

CUSTOMER SERVICE - SERVICE CLIENTÈLE (WORLDWIDE - EUROPE)
MANUFACTURED BY - FABRIQUÉ PAR : 

RECOMMENDATIONS

DO NOT USE THIS UNIT WITHOUT A 60 MICRON

[300 MESH] WATER FILTER* 

OR YOUR WARRANTY WILL BE VOID.

*The 60 micron [300 mesh] water filter (sold separately) 

protects your unit from debris in the water that causes 

scoring to the piston and housing.

KNOW YOUR WATER FLOW! 

GRADUALLY TURN ON THE WATER. 

COUNT THE NUMBER OF CLICKS IN 

15 SECONDS. DO NOT EXCEED 40* CLICKS.

 MAXIMUM PRESSURE 8 bar [110 PSI]

CLICK CHART

Clicks/15sec

l/h

GPM

4

820

3,6

8

1640

7,2

16

3280

14,5

32

6500

29

40

8000

36

Reviews: