![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568018.webp)
18
28-0724/02
30” With MVU
30” Without MVU
2. Connect remaining syrup lines to the left side of the dispenser. On the 30” unit,
syrups 9-12 and the ambient syrups are only used if an MVU is present. Syrups
7-8 and the ambient syrups on the 22” unit are only used if an MVU is present.
1.11
CONTINUINg THE INSTALLATION
Confirm that all configurable valves are set to the correct carb/non-carb option. Refer to section
4.18 for the procedure. The configurable valves are valves 2-5 on the 22” without an MVU and
valves 3-6 on the 30” without an MVU.
1. Install tubular insulation onto the drip tray drain fitting. Insulation should sit flush
against the back of the drip tray. Insulation has a 5/8” ID with a 3/8” wall and is 3/4”
thick:
2. Extend hose to open drain.
3. Install drip tray onto base unit.
Drip Tray
Tubular Insulation
PN 88-0057
Drip Tray Drain Fitting
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...