Self Serve or Crew Serve
The dispenser’s water flow rate can be checked/calibrated using the on-board
computer as a timer.
To check flow rate:
1. Press the top and middle brand buttons at
the same time approximately 5 seconds.
a. The pour cancel button will
illuminate and the shot LED will blink
5 times.
b. The Self-Serve format uses the
same two buttons to check flow rate.
2. Place a ratio cup under the nozzle and
press a brand button.
- Water will pour for 4 seconds.
3. Check for 10 oz of water in the ration cup
(3.0 LEV).
- If above or below 10 oz., adjust the
water/soda flow control and recheck.