4. Drain line must be insulated with a closed cell insulation. Insulation must cover the
entire length of the drain hose, including fittings. The drain should be installed in
such a manner that water does not collect in sags or other low points, as
condensation will form.
5. Install cup rest.
6. Connect power cord to grounded electrical outlet.
7. Test motor operation by pushing ice chute.
8. Clean and sanitize dispenser (see Section 2).
1.11
STARTUP PROCEDURES
1. Turn on water to carbonator pump:
2. Open the relief valve on the carbonator to purge air from the system. Keep open
until water comes out of relief valve.
3. Close relief valve.
4. Activate all valves until a flow of plain water is established from each valve.
5. Turn on CO2 at source and ensure the high pressure regulator is set at 75 PSIG.
6. Empty the carbonator tank by activating a valve until no water comes out.
7. Plug in the carbonator pump motor. The pump will cycle for 5.5 seconds, shut down,
and start again. It will run for additional 5.5 second intervals until the water level
reaches the probe.
8. Activate the carbonated water valves so that the carbonator pump cycles several
times and a healthy flow of carbonated water is established.
Plain water to unit
Soda (carbonated) water to unit
Remote carbonator pump deck
Plain water tee
Water source
Relief Valve
CO2 Inlet Fitting
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...