46
28-0724/02
4.12
TROUBLESHOOTINg
Issue
Cause
Remedy
1. Water leakage around
nozzle.
1. O-ring is not properly
installed above diffuser.
2. O-ring is damaged or
missing.
1. Install or replace o-ring
correctly.
2. Replace o-ring.
2. Leakage between upper
and lower bodies.
1. One or more retaining
screws loose.
2. Paddle arm assemblies
are worn or damaged.
1. Tighten all size retaining
screws.
2. Replace paddle arm
assemblies.
3. Miscellaneous leakage.
1. Gap between parts.
2. Damaged, missing, or
improperly installed o-rings.
1. Tighten appropriate
retaining screws.
2. Replace appropriate o-
rings.
4. Insufficient water flow.
1. Water flow pressure is too
low or restricted.
2. Foreign debris in water
flow controls.
1. Check incoming water
from carbonator to ensure
minimum flowing pressure.
See specifications. Check
stems on mounting block to
ensure it is in fully OPEN
position.
2. Remove water flow control
from upper body and clean
out any foreign materials to
ensure smooth free piston
movement.
5. Insufficient syrup flow.
1. Syrup flowing pressure is
too low or restricted.
2. Foreign debris in syrup
flow controls.
1. Check incoming syrup to
ensure minimum flowing
pressure. See specifications.
Check shutoff on mounting
block to ensure it is in fully
OPEN position.
2. Remove syrup flow control
from upper body and clean
out any foreign materials to
ensure smooth free piston
movement.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...