![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568023.webp)
23
28-0724/02
11. Rotate elbow fitting so that exhaust points downward. Install second elbow fitting
onto open drain tube. Reinstall splash plate and cup rest upon completion.
Completed Condensation Insulation Installation:
12. Reinstall the splash plate, drip tray and cup rest.
1.13
FINISHINg THE DISPENSER INSTALLATION
1. Connect BIB connectors to BIBs.
2. Set the low pressure regulator to 65 PSIG.
3. Activate all valves to purge air from the syrup lines.
4. Fill unit approximately half full with ice. Push chute and check for ice delivery.
5. Finish filling unit with ice.
6. Install top cover.
7. Set ratio for beverage dispensing valves according to manufacturer’s instructions.