![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568079.webp)
79
28-0724/02
6.6
general Troubleshooting
Troubleshooting focuses on two key areas of the dispenser, the carbonation system and the
electronics as the remainder of components such as LEV’s, ice gate, auger, etc are standard
on most new Ice Combo’s.
Issue
Cause
Resolution
1. Push chute and nothing
happens.
1. Dispenser not connected
to power source.
2. Microswitch malfunction-
ing.
3. Wiring harness not
plugged in.
1. Connect dispenser to
power source.
2. Replace microswitch.
3. Plug in wiring harness.
2. Push chute, trap door
opens but motor does not
run.
1. Wiring harness not
plugged in.
2. PC board malfunctioning.
3. Motor malfunctioning.
1. Plug in wiring harness.
2. Replace PC board.
3. Replace motor.
3. Push chute, motor runs
but trap door does not
open.
1. Solenoid not connected to
PC board.
2. Solenoid malfunctioning.
1. Tighten appropriate
retaining screws.
2. Replace appropriate
o-rings.
4. Push chute, trap door
opens, motor runs, but no
ice dispenses.
1. Dispenser is out of ice.
2. Agitator pin is missing or
damaged.
1. Fill unit with ice.
2. Replace agitator pin.
5. Valves do not operate.
1. Toggle switch is off.
2. Transformer tripped.
3. Unit not plugged in.
1. Turn toggle switch on.
2. Reset transformer.
3. Plug in unit.
6. Water in ice bin.
1. Coldplate drain is
obstructed.
2. Drain hose is kinked.
1. Remove drain hose from
fitting to obtain access to
drain.
2. Replace drain hose.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...