65
28-0724/02
3. Fill cup with 1/3 full with ice and place a
cup under the nozzle.
4. Push and hold a drink ”size” button until
the cup is full.
-Repeat this step for each of the other
size cups.
-Select other brands and repeat these
steps for each of them.
5. Press the “Pour Cancel” button to save
the programming and exit programming
mode.
Note:
The most recent programming entries will
be saved automatically after 60 seconds if
no other buttons are pressed.
Check/Adjust Flavor Shots – Self Serve
Flavor shots should be adjusted so that
approximately ten ml of syrup pours each
time the button is pushed. To check
dispensed amount:
1. Use a 50 ml graduated cylinder.
2. Place the graduated cylinder under the
nozzle.
3. Press the Flavor Shot button one time
- Approximately ten ml should dispense. If
more or less than ten ml, adjust the flow
control.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...