Issue
Cause
Remedy
9. Valve will not shut off.
1. Cup lever may be sticking
or binding.
2. If LEV, switch not
actuating properly.
3. If LEV, solenoid armature
not returning to bottom
position.
4. Debris or damage or
paddle arms.
1. Correct or replace lever.
2. Check switch for free
actuation.
3. Replace defective solenoid
armature or spring.
4. Remove debris and/or
replace damaged paddle
arms.
10. Excessive foaming.
1. Incoming water or syrup
temperature too high.
2. Water flow rate too high.
3. Nozzle and diffuser not
clean.
4. Nozzle and diffuser not
properly installed.
5. CO
2
pressure too high.
1. Correct at dispenser.
2. Re-adjust and reset Brix.
3. Remove and clean.
4. Remove and install
properly.
5. Check for proper pressure
setting.
11. No syrup-out light (if
equipped).
1. Burned out or
malfunctioning lamp.
1. Replace harness.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...