![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568059.webp)
59
28-0724/02
5.2
Program Multi-Valve Unit (MVU)
Set MVU Buttons as Carbonated, Non-Carbonated, or Flavor Shot Only
Refer to install guidelines for account specific brands.
Self-Serve
The MVU can be programmed to serve carbonated or non-carbonated beverages as well as a
flavor shot from each of the beverage positions on the valve.
To enter the programming mode on the MVU and assign water type to each individual brand
(Soda or Plain Water):
1. Press both top and bottom “PUSH”
buttons at the same time on the MVU
panel for 5 seconds. On some dispensers
the top button may be hidden (no “PUSH”
label present). In this case, the button can
be used to enter the programming mode
and the button should be set to No Water
(Light Off). The light for the top hidden
button will be visible when lit.
Lights on = Plain Water
Lights flashing slowly = Carb Water
Lights flashings quickly = Flavor Shot
Lights off = No Water
2. If the button light is off, press a “PUSH”
button one time to change to a non-carb
beverage.
LED will illuminate and stay on for non-carb
beverages.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...