![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568066.webp)
66
28-0724/02
Check/Adjust Flavor Shots – Crew Serve
Flavor shot portions can be adjusted using
the MVU touchpad and a graduated cylinder.
Refer to your project plan to determine shot
size for your customer. To adjust flavor
shots:
1. Press the small and extra large cup
buttons at the same time.
-Hold for 5 seconds or until the pour/cancel
button illuminates.
2. Press the shot button to activate the
brands for shots.
3. Press a “Brand” button to activate for
shot mode.
- The brand button will illuminate.
Note:
If brand is not enabled for shot mode, the
LED light will blink twice and turn off.
4. Place a 50 ml graduated cylinder under
the nozzle.
5. Press and hold XL portion button until
the portion size is achieved.
-Target is 30 ml (1 oz) of syrup for an XL
portion.
-Repeat steps 2 through 4 for each of the
other brands.
Note:
The other size buttons are proportioned
based on the amount poured in XL mode:
6. Press “Pour Cancel” button to save.
Note:
You have 60 seconds to save the
programming after all changes have been
made or the programming will save
automatically.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...