![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568087.webp)
87
28-0724/02
6.12
Auger Motor Removal
Option 1:
The auger motor/gear box can
be
removed the traditional way by
disconnecting the
auger from the motor. The steps are as
follows:
1. Unplug the dispenser.
2. Remove Rue Pin from locking pin an
pull locking pin out of auger.
3. Remove wires from switch.
4. Remove lower ice chute.
5. Spread ears on chute and pull down.
6. Remove splash panel.
7. Remove agitator motor cover plate (two
screws).
8. Disconnect wire harness from auger
motor.
9. Remove auger motor retaining bracket
(four screws).
10.Pull out motor/gear box.
Reverse the steps to install a new
motor/gear box.
Note:
When reinstalling the motor, be sure to lock
the rue pin (see diagram at right), and
ensure that the shaft seal is in place.
Lock by moving bent end to opposite side
of straight end. When locked, clip will
appear as shown at right.
Option 2:
The auger motor can be
removed without entering the ice bin. This
eliminates the need to remove any ice
making equipment from the top of the
dispenser or remove ice from the bin itself.
Summary of Contents for BEVARIETY MCY-22
Page 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Page 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Page 49: ...49 28 0724 02 Notes ...
Page 69: ...69 28 0724 02 Notes ...
Page 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Page 86: ...86 28 0724 02 ...
Page 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Page 90: ......
Page 91: ......
Page 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Page 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...