GH-3100
Installation & Operation Manual
TP-559
Installation
Page 2-3
Revision K
March 30, 2017
7.
Insert indicator in instrument panel.
8.
Secure the indicator by first tightening (10 to 12 in-lbs.) mounting clamp via two corner screws (8-
32, lower left and upper right), followed by placing and tightening (6 to 8 in-lbs.) two screws (6-32)
in opposite corners of the clamp tightening screws.
NOTE
Installer must take into consideration the length of the wiring harness
before installing the indicator into the instrument panel. The connection
of mating connector may be required before installation of the unit.
9.
This completes the indicator installation. Refer to paragraph 2.3.3 for electrical connections.
2.3.2 DCM-3100 Detachable Configuration Module
Connect the Detachable Configuration Module to the wiring harness of the GH-3100 via the attached
chain. Refer to Figure 2-1 for outline dimensions.
NOTE
Before installation, verify that the ID Plate on Configuration Module has
the correct aircraft effectivity for that particular aircraft.
Figure 2-1: DCM-3100 Outline Dimensions